These Fans are used by the Tea Industry for Withering of
green leaf. Size of fans required, depends on overall parameters i.e. Trough
size, thickness of leaf spread, elevation of factory and CFM requirement,
normally calculated @ 25 CFM / FT at 1/2"Wg. pressure.
|
|
|
APPLICATION : Withering fans come in five popular sizes to suit the size of trough you can conveniently make (also suitable for sorting room applications as exhaust fans and for Java Tunnels).
CONSTRUCTION : Single piece 6-bladed cast aluminum alloy impellers house in a heavy sheet metal casting. Direct driven by a totally enclosed fan cooled motor of international make, the motor sits on a sturdy 'T' shaped base made of thick plate. Impellers bore provided with cast iron bush to ensure perfect fit on motor shaft. An inlet protection guard is standard on all Withering axial fans.
TESTING : Each fan is dynamically balanced and individually checked in the wind tunnels for rated air volumes, static pressure and amperage consumption. Withering fan performance are rated at sea level.
ADVANTAGES :
Withering cast impeller fans have the obvious advantage of sturdiness and a
constant reliable air delivery without any chance of overloading the motor as in
the case of adjustable vane fans.
SPECIFICATIONS
| MODEL | SIZE | PRESSURE | POWER CONSUMPTION | MOTOR/RMP | STARTER |
| T-1004 | 40" | 20000 | 2.9 | 3 HP/1000 | DOL |
| T-1025 | 41" | 26500 | 4.2 | 5 HP/1000 | MSD |
| T-1112 | 44" | 30000 | 4.8 | 5 HP/1000 | MSD |
| T-1222 | 48" | 39000 | 6.3 | 7.5 HP/1000 | MSD |
| T-1200 | 48" | 25000 | 2.8 | 3 HP/1000 | DOL |
| T-1200(A) | 48" | 29000 | 4.7 | 5 HP/1000 | MSD |
| T-1312 | 52" | 43500 | 7.0 | 7.5 HP/1000 | MSD |